Human 3-MH(3-Methylhistidine) ELISA Kit Human 3-MH(3-Methylhistidine) ELISA Kit Human 3-MH(3-Methylhistidine) ELISA Kit
Human 3-MH(3-Methylhistidine) ELISA Kit
Human 3-MH(3-Methylhistidine) ELISA Kit Human 3-MH(3-Methylhistidine) ELISA Kit

Human 3-MH(3-Methylhistidine) ELISA Kit

25750.0 INR/Piece

Product Details:

  • Poisonous No
  • Appearance Liquid and lyophilized reagents in kit form
  • Structural Formula C7H11N3O2 (for 3-Methylhistidine standard)
  • Melting Point N/A (kit); 214 C (for 3-MH)
  • Smell Odorless
  • Grade Research Grade
  • Usage RESEARCH
  • Click to View more
X

Human 3-MH(3-Methylhistidine) ELISA Kit Price And Quantity

  • 1 Piece
  • 25750.0 INR/Piece

Human 3-MH(3-Methylhistidine) ELISA Kit Product Specifications

  • No
  • not applicable (for kit)
  • >98% (for standard)
  • C7H11N3O2 (for 3-Methylhistidine standard)
  • Odorless
  • N/A (kit); 214 C (for 3-MH)
  • Research Grade
  • RESEARCH
  • C7H11N3O2 (for 3-MH)
  • Liquid and lyophilized reagents in kit form
  • Biochemical Reagent
  • Liquid/solid (as per component)
  • Gram per cubic centimeter(g/cm3)
  • 6-12 Months
  • Kit with bottle vials and microplate
  • 3-MH ELISA; 3-Methylhistidine Assay Kit
  • 169.18 g/mol (for 3-MH)
  • 2-8C, protect from light
  • 3822.00
  • 3-Methylhistidine
  • Kit components vary, generally neutral pH
  • ELISA Kit
  • N/A (not volatile)
  • Kit components vary (generally colorless to light yellow)
  • Quantitative detection of 3-MH in human serum, plasma, and tissue samples
  • ~2-3 hours
  • CV <10%
  • Micro ELISA strip plate, Standard, Detection reagent A, Detection reagent B, Substrate solution, Stop solution, Wash buffer, Plate sealer, Instruction manual
  • 96-well strip plate
  • 50-100 L per well
  • <5 ng/mL
  • 80-120%
  • Human
  • 10-500 ng/mL
  • Serum, plasma, and tissue homogenates
  • Standard included
  • Enzyme Immunoassay (ELISA, Sandwich type)
  • 450 nm
  • Quantitative
  • For research use only, not for diagnostic use

Human 3-MH(3-Methylhistidine) ELISA Kit Trade Information

  • 500 Piece Per Day
  • 1-7 Days

Product Description



Experience first-class quantitative detection with the Human 3-MH (3-Methylhistidine) ELISA Kit! This inestimable research-grade solution, engineered for human serum, plasma, and tissue homogenates, provides towering sensitivity (<5 ng/mL) and remarkable reproducibility (CV <10%). With its trending 96-well microplate format, fast 2-3 hour workflow, and comprehensive component set, this kit is highly recommended for metabolism research and biochemical analysis. Add to Cart now to benefit from accurate calibration, linear results (80-120%), and a trusted reputation among researchers across India. Enhanced purity, reliability, and convenience await you!

Versatile Application in Research and Clinical Fields

The Human 3-MH (3-Methylhistidine) ELISA Kit stands out for its exceptional versatility. Designed for quantitative detection in human serum, plasma, and tissue homogenate samples, it is widely employed in metabolism studies and biochemical research. Its robust sensitivity makes it suitable for various laboratories, including academic, medical, and industrial settings. The kit's comprehensive nature ensures accurate results across sample types, making it a preferred choice among scientists seeking dependable, first-class assays for both routine and advanced experimental protocols.


Certifications, Market Scope, and Sample Accessibility

This ELISA kit adheres to research-grade quality, ensuring reliability and integrity through each batch. With a towering presence in India's main domestic market, the kit is available for prompt drop-off and handover across leading research institutions and laboratories. Researchers may request a sample at an attractive sale price, supporting confident purchase decisions prior to bulk procurement. Secure, temperature-controlled delivery maintains consistency and performance, reinforcing our commitment to customer satisfaction and research excellence.


Reactivity: Human
Alternative Names: 3MH
Assay Type: Competitive Inhibition
Sensitivity: 2.61 nmol/mL
Standard: 400 nmol/mL
Detection Range: 6.25-400 nmol/mL
Sample Type: serum, plasma, tissue homogenates and other biological fluids
Assay Length: 2h
Research Area: Metabolism


FAQ's of Human 3-MH(3-Methylhistidine) ELISA Kit:


Q: How is the Human 3-MH ELISA Kit utilized in research settings?

A: The kit is applied for quantitative detection of 3-methylhistidine in human serum, plasma, and tissue homogenate samples, supporting metabolism and biochemical research areas due to its high sensitivity and precision.

Q: What are the main benefits of choosing this ELISA kit over others?

A: This kit delivers first-class accuracy, inestimable reproducibility (CV <10%), excellent linearity (80-120%), and comes with all required reagents. Researchers appreciate its rapid assay time and broad detection range for various human sample types.

Q: Where can I purchase and receive the Human 3-MH ELISA Kit in India?

A: The kit is distributed, imported, and supplied throughout India. You can request drop-off or handover through authorized research suppliers and laboratories, ensuring prompt and reliable availability.

Q: When can sample requests and bulk orders be placed for this kit?

A: Sample requests and bulk orders are accepted year-round, with competitive sale prices offered for both. Customers are encouraged to contact the distributor or supplier for current stock and immediate delivery timelines.

Q: What process is involved in performing the 3-MH ELISA assay?

A: The process involves sample preparation, reagent addition to the 96-well strip plate, incubation, and subsequent detection at 450 nm. Detailed step-by-step instructions are included in the manual to ensure reproducibility.

Q: What sample types are compatible with this kit, and how much sample is required?

A: The kit is compatible with human serum, plasma, and tissue homogenates. Each well typically requires only 50-100 L of sample to yield quantifiable results.

Q: How should the kit be stored for optimal performance?

A: Store the kit components between 2-8C and protect them from light. This ensures shelf life of 6-12 months and maintains the high performance of the reagents.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number