call-us
Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit
Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit
Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit

Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit

25749.0 INR/Piece

Product Details:

  • Usage Research
  • Shelf Life 6-12 Months
  • Grade Research Grade
  • Application Quantitative detection of VE-Cadherin in rat samples
  • Smell Odorless
  • Poisonous Non-poisonous (For In vitro Research Use Only)
  • Appearance ELISA Plate with Reagents
  • Click to View more
X

Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit Price And Quantity

  • 1 Piece
  • 25749.0 INR/Piece

Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit Product Specifications

  • Research
  • 6-12 Months
  • ELISA Kit
  • Research Grade
  • Quantitative detection of VE-Cadherin in rat samples
  • Non-poisonous (For In vitro Research Use Only)
  • Odorless
  • ELISA Plate with Reagents
  • As per kit contents, usually colorless to light yellow
  • CD144, Cadherin-5
  • 6.8-7.4 (Reconstituted buffers)
  • Kit Form (Multiple Vials/Plate)
  • VE-Cadherin (Vascular Endothelial Cadherin)
  • Immunoassay Kit
  • 2-8C (Some components may require -20C)
  • N/A (Protein mixture/Antibody kit)
  • Liquid and Lyophilized Reagents
  • > 98% (assay dependent)
  • 3822.00
  • Serum, Plasma, Tissue Homogenates, Cell Culture Supernatant
  • Use personal protective equipment, avoid contamination, follow biological sample handling protocols
  • Rat
  • Custom; varies by supplier
  • Typically < 0.10 ng/mL
  • Intra-assay CV <10%, Inter-assay CV <12%
  • Follow manual for buffer and reagent reconstitution steps
  • Detects and quantifies rat vascular endothelial-cadherin in biological samples
  • 50-100 L/well
  • Antibody sandwich enzyme-linked immunosorbent assay (ELISA)
  • Pre-coated ELISA Plate, Standards, Detection Antibody, HRP-conjugate, Substrate, Stop Solution, Wash Buffer, Sample Diluent, Instruction Manual
  • Approx. 0.156 ng/mL - 10 ng/mL
  • Each kit tested for sensitivity, specificity, and reproducibility
  • Provided with kit
  • Microplate reader (450 nm), pipettes, wash bottle or ELISA washer
  • Sandwich ELISA, Colorimetric (450 nm)

Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit Trade Information

  • 2 Week

Product Description



The Rat VE-Cadherin (Vascular Endothelial Cadherin) ELISA Kit is a prime, top-rated solution for quantitative detection of CD144 in rat samples. Designed for unbeatable accuracy, the premier kit employs a sandwich ELISA method with a colorimetric readout at 450 nm. Redeem consistent, reliable results with a complete kit comprising pre-coated plates, standards, detection antibodies, and HRP conjugate. Suitable for serum, plasma, tissue homogenates, and cell culture supernatant, this research-grade kit ensures high sensitivity (<0.10 ng/mL), exceptional precision, and comes with a detailed instruction manual for effortless order and usage.

Versatile Applications for Research Innovation

The Rat VE-Cadherin ELISA Kit is tailored for laboratories, academic institutions, and biotechnology research centers. This kit excels in detecting and quantifying vascular endothelial-cadherin in diverse rat biological samples-supporting applications in vascular biology, cell signaling, and endothelial function studies. With high purity and specificity, its research-grade design is suitable for quantitative analysis in serum, plasma, tissue homogenates, and cell culture supernatant. Ideal for in vitro experiments, it streamlines workflow in advanced research projects.


Global Reach and Reliable Supply Chain

Dispatched efficiently from premier suppliers in India, the Rat VE-Cadherin ELISA Kit commands robust market value across the globe. Its main export markets include North America, Europe, and Asia, ensuring wide accessibility. Orders are drop-off ready at key FOB ports, optimizing transit times. Regular availability meets the high supply demand for laboratories, while distributors and importers benefit from timely deliveries and competitive market presence within the immunoassay sector.


Reactivity: Rat
Alternative Names: CD144; 7B4; Cadherin 5 Type 2; VE-Cadherin; Cadherin,Vascular Endothelial; CDH5; Cadherin 5
Assay Type: Sandwich
Sensitivity: 1.21 ng/mL
Standard: 200 ng/mL
Detection Range: 3.13-200 ng/mL
Sample Type: serum, plasma, tissue homogenates, cell lysates and other biological fluids
Assay Length: 3.5h


FAQ's of Rat VE-Cadherin(Vascular Endothelial Cadherin) ELISA Kit:


Q: How does the Rat VE-Cadherin ELISA Kit detect target protein in samples?

A: The kit utilizes a sandwich ELISA technique: capture antibodies immobilize the target protein (VE-Cadherin), followed by detection using an HRP-conjugated antibody. Upon substrate addition, a colorimetric reaction is measured at 450 nm.

Q: What types of biological samples can be used with this kit?

A: This ELISA kit is validated for rat serum, plasma, tissue homogenates, and cell culture supernatant, providing flexibility to researchers across different study types.

Q: When should I use this kit in my research workflow?

A: Use the kit during experiments requiring quantitative measurement of VE-Cadherin, such as studies on vascular integrity, endothelial cell interactions, and targeted biomarker analysis in rat models.

Q: Where is the best place to set up the assay for optimal results?

A: Perform the assay in a controlled laboratory setting, using a microplate reader (450 nm) and standard ELISA equipment to ensure accuracy and repeatability.

Q: What is the process for reconstituting buffers and reagents?

A: Follow the detailed instructions provided in the kit manual for reconstitution steps-use appropriate buffers, maintain pH, and handle reagents with care to prevent contamination.

Q: What are the benefits of using this premier ELISA kit for VE-Cadherin detection?

A: Benefits include high sensitivity, precise quantification, reliability, quick turnaround with a 3.5-hour assay duration, and comprehensive quality control for reproducible research outcomes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+